REAGEN LLC
Email reagenkits@gmail.com TEL: 1-619-389-8888
Home > products > Drug Residue Test Kit >
Kanamycin ELISA Test Kits Suppliers fast Operating time High recovery
  • Kanamycin ELISA Test Kits Suppliers fast Operating time High recovery
  • Kanamycin ELISA Test Kits Suppliers fast Operating time High recovery
  • Kanamycin ELISA Test Kits Suppliers fast Operating time High recovery
  • Kanamycin ELISA Test Kits Suppliers fast Operating time High recovery

Kanamycin ELISA Test Kits Suppliers fast Operating time High recovery

Place of Origin USA
Brand Name REAGEN
Certification FAPAS
Model Number RND99033
Product Details
Specification:
96 Test
Package:
Color Packing
Shelf Life:
12 Months
High Recovery:
>80%
Accuracy:
95%
Operating Time:
Fast
High Light: 

Kanamycin elisa test kits suppliers

,

Kanamycin ELISA Kit High accuracy

,

High Recovery Kanamycin ELISA Kit

Payment & Shipping Terms
Minimum Order Quantity
5 kits
Price
Negotiable
Packaging Details
color packing
Delivery Time
5-7 days
Payment Terms
T/T
Supply Ability
100 kits per month
Product Description

                                                                             Kanamycin ELISA Test Kit

                                                                                       RND99033

 

Warnings and Precautions

 

  • The standards contain Kanamycin. Handle with particular care.
  • Do not use the kit past the expiration date.
  • Do not intermix reagents from different kits or lots except for components with the same part No’s within their expiration dates. ANTIBODIES AND PLATES ARE KIT-AND LOT-SPECIFIC.
  • Try to maintain a laboratory temperature of 20°–25°C (68°–77°F). Avoid running assays under or near air vents, as this may cause excessive cooling, heating and/or evaporation. Also, do not run assays in direct sunlight, as this may cause excessive heat and evaporation. Cold bench tops should be avoided by placing several layers of paper towel or some other insulation material under the assay plates during incubation.
  • Make sure you are using only distilled or deionized water since water quality is very important.
  • When pipetting samples or reagents into an empty microtiter plate, place the pipette tips in the lower corner of the well, making contact with the plastic.
  • Incubations of assay plates should be timed as precisely as possible. Be consistent when adding standards to the assay plate. Add your standards first and then your samples.
  • Add standards to plate only in the order from low concentration to high concentration as this will minimize the risk of compromising the standard curve.
  • Always refrigerate plates in sealed bags with a desiccant to maintain stability. Prevent condensation from forming on plates by allowing them equilibrate to room temperature (20 – 25°C / 68 – 77°F) while in the packaging.

 

Note: Dilution Factor:10